Physical Controls & Display — Mysa for In-Floor Heating

Last updated: July 6, 2026

Your Mysa for In-Floor Heating has front-facing temperature controls and side-mounted GFCI safety controls.

Front Controls

Control

Function

Up arrow

Increase temperature setpoint

Down arrow

Decrease temperature setpoint

Hold to set Off Mode (Dash - on screen)

Side GFCI Controls

Control

Function

Test button

Tests the GFCI protection circuit

Reset button

Resets after a GFCI trip

Trip indicator light

Illuminates when GFCI has tripped

Display

The display shows the current temperature based on your selected mode:

  • Ambient mode: Shows room temperature (5–30°C)

  • Floor mode: Shows floor surface temperature (up to 40°C)

During pairing, the display shows a Bluetooth symbol to indicate pairing mode is active.

Testing the GFCI Monthly

Test your GFCI protection monthly to ensure proper operation:

  1. Verify the trip indicator light is off (if on, press Reset)

  2. Turn the heater to maximum temperature and wait 10 minutes

  3. Press the Test button

  4. Verify the trip indicator illuminates

  5. Wait 5–10 minutes to confirm the floor heater cools

  6. Press the Reset button to end the test

Tip Set a monthly reminder to test your GFCI. Regular testing ensures the safety circuit is functioning properly.

Manual Operation Without Wi-Fi

If your Mysa loses Wi-Fi connection, you can still control the temperature manually using the up and down arrows on the front of the thermostat.