Why Your HVAC Might Not Be Responding

If your heating, cooling, or fan doesn’t start when expected, don’t worry — most issues are simple wiring or configuration mismatches, not hardware failures.

The most common causes include:

  • Incorrect configuration code (system type not matched correctly)

  • Wiring misplacement (e.g., W vs O/B terminals)

  • Blown furnace fuse or open blower door interlock

  • Power interruption at the breaker or HVAC board

  • Equipment-specific conditions (defrost, delay, or safety lockout)

Why this matters: In most cases, you can fix HVAC response issues by confirming wiring and configuration — no tools beyond a screwdriver and smartphone required.


Step 1: Initial Checks

Before changing settings or wiring, start with these quick safety and power checks.

1. Confirm Mode and Setpoint

Ensure your thermostat is in the correct mode (Heat, Cool, or Auto).

Raise or lower the setpoint by 2–3°C (4–6°F) beyond current room temperature to trigger a call for heating or cooling.

Wait up to 90 seconds — many HVAC systems include a short delay before responding.

2. Check Power to Equipment

Confirm your breaker is ON for the furnace, air handler, or condensing unit.

Ensure the blower door panel is properly closed; the interlock switch must be pressed for the system to power.

3. Inspect the Control Board Fuse

Open the furnace access panel (if safe to do so).

Look for a 3–5A automotive-style fuse on the low-voltage circuit board.

Replace if blown using the same rating.

Safety Note: Always cut power at the breaker before touching wiring or internal components.


Step 2: Test System

If power and mode look correct, the next step is to verify signals through the Mysa app.

Open the Mysa app → Select your thermostat.

Adjust Mode to Heat or Cool.

Run the Heat, Cool, and Fan modes and verify these are operating as expected.


Interpreting Results

ResultWhat It MeansWhat to Do
SuccessHVAC responded correctly.Setup is complete — no further action.
No ResponseNo signal from thermostat to control board.Check wiring, fuse, and C-wire.
Incorrect OutputOpposite behavior (e.g., cooling during heat test).Review configuration code and reversing valve wiring.

Step 3: Verify Wiring & Configuration

If tests fail or produce unexpected results, it’s time to check wiring and system configuration.


Wiring Verification

TerminalTypical WireFunction
R / RC / RHRed24 V power feed from transformer
CBlue or blackCommon return for 24 V circuit
Y / Y1 / Y2YellowCompressor (cooling) control
W / W1 / W2WhiteHeating call
GGreenFan relay
O / BOrange / BlueHeat pump reversing valve
S1 / S2VariesWired sensors (if installed)

Check that wires are fully inserted and tightened into the correct terminals. Use your pre-install photo as a reference.


Configuration Code Check

Your configuration code tells Mysa what kind of HVAC system you have.
If heating or cooling behaves backwards, or the fan doesn’t run, your code may need adjustment.

Open the Mysa app → Device Settings → System Configuration.

Confirm the current code matches your system:

System TypeExample CodeNotes
1 Heat / 1 Cool11BMost standard furnaces + AC systems
Heat Pump with O (cooling energized)31PCommon heat pump configuration
Heat Pump with B (heating energized)31LUse if heating/cooling reversed during test
Boiler / Radiant21BHeating only systems
Dual Transformer41BSpecial setups; professional install required

Quick Fix: If your heat pump cools when it should heat, switch between 31P ↔ 31L and re-run the heat test.


Step 4: Check Special Cases

Heat Pump Reversing Valve Behavior

If your system uses a heat pump, the reversing valve determines whether the system is in heating or cooling mode.

  • O systems: Energize the valve for cooling.

  • B systems: Energize for heating.

If heating and cooling are reversed, change from 31P → 31L in the configuration settings and retest.


Step 5: When to Call a Professional

If you’ve confirmed wiring and configuration but the HVAC still doesn’t respond, your system may have a mechanical or electrical issue that requires a certified technician.

Call a Pro If:

  • The compressor or furnace doesn’t start even with correct wiring.

  • The blower fan won’t run independently.

  • The system has two transformers (common in complex or zoned setups).

  • You hear clicks or short cycling but no air movement.

  • You suspect a control board failure or faulty transformer.

Pro Tip: Before calling, have your configuration code, wiring photo, and any in-app test results ready — these help your technician diagnose faster.