Compatibility Quick Check — Mysa for In-Floor Heating
Last updated: August 26, 2026
Run through this before you buy. It takes a few minutes and confirms whether Mysa for In-Floor Heating can control your system.
You are likely compatible if
Your floor heating is electric — a heating mat or heating cable, not a hot-water system
The circuit is single-phase 120V, 208V, or 240V
Your system wattage is within the limits below
The circuit is not already GFCI-protected — Mysa has its own built-in GFCI
The wiring is copper, not aluminum
A floor sensor is installed, or you can route one into the heated floor
Maximum load by voltage
120V — up to 1,900W
208V single-phase — up to 3,328W (16A)
240V — up to 3,800W (15A)
Check the rating on the heating mat or cable label, the cold lead tag, the manufacturer documentation, or the label on the relay panel or junction box.
You are not compatible if
The system is hydronic (hot water)
The system is 24V or another low-voltage control
It is a three-phase 208V system
It is forced air, a heat pump, or gas or oil heating
It is baseboard, convector, or fan-forced heating — use Mysa for Baseboards instead
The wattage is above the limit for your voltage
For the full detail, see In-Floor Heating Compatibility Guide. Still not sure? Contact support@getmysa.com with your heating system voltage, wattage, and photos of the existing thermostat wiring.