Compatibility Guide — for Central HVACUpdated 7 days ago

Mysa for Central HVAC Compatibility and Configuration Overview

Mysa for Central HVAC is a 24-volt (low-voltage) smart thermostat designed for central heating and cooling systems. Because its features depend on your system’s wiring and voltage, it’s important to confirm compatibility before installation. This guide combines a clear compatibility overview with a detailed Configuration Code Matrix for both homeowners and installers.

For Installers: Mysa’s Installation Training materials include wiring diagrams, terminal layouts, and best practices referenced below. For homeowners, see the quick checklist at the bottom for easy pre-purchase checks.


Supported HVAC System Types

Below are the HVAC system types Mysa for Central HVAC supports, along with wiring notes and configuration recommendations.

System TypeSupportedHeating / Cooling TypeStagesFan ControlRecommended Config Code(s)C-Wire or CWANotes & Requirements
Forced-Air Furnace (Gas/Oil)✅ Yes1H / 1C1 – 2Single / Multi-speed11B, 61BRequired (CWA if missing)Mysa manages fan logic and staging automatically.
Forced-Air Furnace (Electric)✅ Yes1H / 1C1 – 2Single / Multi-speed21B, 71BRequired (CWA if missing)Uses faster cycle rates; staging controlled via app.
Heat Pump (with / without Aux Heat)✅ Yes1H / 1C + Aux1 – 2 + AuxAuto / Multi-speed31P, 31L, 81P, 81LRequired (CWA if missing)Use 31P for O-valve (energized for cooling), 31L for B-valve (energized for heating).
Boiler / Radiant (Hydronic)✅ Yes1H / 0C1 – 241B, 91BRequired (CWA if missing)Ideal for radiant heat or fan-coil units with hydronic control.
Hybrid / Dual Systems (Boiler + Air Handler)⚠️ Partial1H / 1C (Dual Transformer)1 – 2Single41B + 11BC on both transformersMay require isolation relay; professional install recommended.
Fan Coil / PTAC (24 V)⚠️ Partial1H / 1C or Fan only1G1 / G2 / G345B, 55BRequiredVerify manufacturer wiring; supports multi-speed mapping.
Line-Voltage Heaters (Baseboards / In-floor Electric)❌ NoUse Mysa for Baseboard; Central HVAC is for 24V systems only.
Millivolt Systems (Legacy Gas)❌ NoNot compatible with millivolt circuits.
Communicating / Proprietary Thermostats❌ NoDigital communicating protocols not supported.
Systems with Separate O & B Wires❌ NoMay require professional rewiring or alternate control solution.

Feature & Electrical Support Summary

  • Multi-stage Heat/Cool: W1/W2 and Y1/Y2 supported; staging adjustable in the Mysa app.

  • Multi-speed Fan: G1–G3 supported on compatible fan-coil or PTAC systems.

  • Aux / Emergency Heat: Automatically detected for heat-pump systems.

  • Sensor Terminals (S1/S2): Reserved for future hardwired sensor support (Coming soon.)

  • Voltage: 24 V AC only (low-voltage HVAC systems).

  • C-Wire: Required — use the Mysa C-Wire Adapter (CWA) if missing.


Quick Compatibility Checklist

  • Take a photo of your existing thermostat wiring and your HVAC control board.

  • Count and label wires (R, C, W/W2, Y/Y2, G, O/B).

  • Check for a C wire — if missing, plan to use the C-Wire Adapter (CWA).

  • Confirm your system type: forced-air, boiler/radiant, heat pump, or fan-coil/PTAC.

  • If unsure, share your wiring photo with Mysa Support.

Need help? Upload your wiring photo at help.getmysa.com or email [email protected] for a quick compatibility check.