Does Mysa Smart Thermostat keep the fan running after heating or cooling stops?

Last updated: November 23, 2026

Does Mysa Smart Thermostat keep the fan running after heating or cooling stops?

Mysa Smart Thermostat does not add an automatic fan dissipation, fan overrun, or purge-delay period after a heating or cooling call ends.

What happens at the end of a cycle

When Mysa reaches the target temperature, it ends the heating or cooling call and the fan call at the same time. On many low-voltage systems, this means the outdoor equipment and indoor blower stop together.

Why an older thermostat may have behaved differently

Some thermostats, including some Honeywell models, include a built-in fan overrun feature that keeps the fan running for a short time after heating or cooling stops. That can move remaining warm or cool air through the ducts.

Mysa does not currently provide a customer setting for adding this post-cycle fan delay. Some HVAC systems handle blower timing at the equipment control board instead of at the thermostat.

What to check

  • If your previous thermostat kept the fan running for a short time and Mysa stops the fan immediately, this may be expected Mysa behavior.

  • If your system requires a fan delay for safe or correct operation, check the HVAC equipment manual or ask a qualified HVAC professional whether the equipment can manage fan timing directly.