Flame Percentage Calculations
When Mysa turns your heater on it only does so for a specific amount of time, which is called a cycle.
Mysa calculates the percentage based on the amount of time the heater will be on for the cycle duration. In the tables below are the detailed flame states, duty cycles, and the corresponding times.
Flame Icon with 15 Second Cycle Time (Baseboard Mode) |
|||
Flame State |
Duty Cycle(%) |
On-Time (seconds) |
Off Time (seconds) |
0 Flames |
0 - 10 |
0 |
15 |
1 Flame |
10 - 20 |
1.5 |
13.5 |
20 - 30 |
3 |
12 |
|
30 - 40 |
4.5 |
10.5 |
|
2 Flames |
40 - 50 |
6 |
9 |
50 - 60 |
7.5 |
7.5 |
|
60 - 70 |
9 |
6 |
|
3 Flames |
70 - 80 |
10.5 |
4.5 |
80 - 90 |
12 |
3 |
|
90 - 100 |
13.5 |
1.5 |
|
100 |
15 |
0 |
Flame Icon with 3 minutes Cycle Time (Fan-forced Slow Mode) |
|||
Flame State |
Duty Cycle (%) |
On-Time (seconds) |
Off Time (seconds) |
0 Flames |
0 - 10 |
0 |
180 |
1 Flame |
10 - 20 |
18 |
162 |
20 - 30 |
36 |
144 |
|
30 - 40 |
54 |
126 |
|
2 Flames |
40 - 50 |
72 |
108 |
50 - 60 |
90 |
90 |
|
60 - 70 |
108 |
72 |
|
3 Flames |
70 - 80 |
126 |
54 |
80 - 90 |
144 |
36 |
|
90 - 100 |
162 |
18 |
|
100 |
180 |
0 |
Flame Icon with 4 Minutes Cycle Time (Fan-forced Medium Mode) |
|||
Flame State |
Duty Cycle (%) |
On-Time (seconds) |
Off Time (seconds) |
0 Flames |
0 - 10 |
0 |
240 |
1 Flame |
10 - 20 |
24 |
216 |
20 - 30 |
48 |
192 |
|
30 - 40 |
72 |
168 |
|
2 Flames |
40 - 50 |
96 |
144 |
50 - 60 |
120 |
120 |
|
60 - 70 |
144 |
96 |
|
3 Flames |
70 - 80 |
168 |
72 |
80 - 90 |
192 |
48 |
|
90 - 100 |
216 |
24 |
|
100 |
240 |
0 |
Flame Icon with 6 minutes Cycle Time (Fan-forced Long Mode) |
|||
Flame State |
Duty Cycle (%) |
On-Time (seconds) |
Off Time (seconds) |
0 Flames |
0 - 10 |
0 |
360 |
1 Flame |
10 - 20 |
36 |
324 |
20 - 30 |
72 |
288 |
|
30 - 40 |
108 |
252 |
|
2 Flames |
40 - 50 |
144 |
216 |
50 - 60 |
180 |
180 |
|
60 - 70 |
216 |
144 |
|
3 Flames |
70 - 80 |
252 |
108 |
80 - 90 |
288 |
72 |
|
90 - 100 |
324 |
36 |
|
100 |
360 |
0 |